• Plyfloor - ForestOne Block all edges of standard "square edge" Ecoply structural plywood. o. Block if the floor is being used as a diaphragm for lateral wind and earthquake resistance with fixin. g transfer shear across the joints. In this case, details should be specified on dings. o. Use blocking "on the flat" to provide gaps where air flow is needed for

  • Downloads for Designers, Architects & Builders Carter Holt Harvey ecoply bracing & ecoply barrier bracing systems. For timber floors you must use a single type 17 125mm 14 gauge bugle head screw instead of 90mm hand or power driven nails. All fixing centres and lo ions should be as NZS 3604:2011 and its amendments.

  • PDF PLYfloor Installation Guide - Dindas flooring sheet, or glue-nail the floor to increase stiffness and minimise squeaking, and stretch the foil flat under the joists. Use timber sheets or strips of a low grade of non-structural plywood 7 mm pallet grade to fix the foil to the underside of the floor. Alternatively, use foil backed panels under the floor …

  • hyJOIST I-Beam LVL Floor joists, rafters NZ Made designIT for Commercial Floors Installation Guide This guide provides a variety of details specific to the use of Futurebuild LVL floor systems for commercial, industrial and other heavily loaded floors. designIT for Commercial Floors is a software tool for all building practitioners designing with the Futurebuild LVL range and other selected materials.

  • Product Scope Building Regulations ECOPLY - Masterspec Jun 2 , 20 9 Concrete floor end stud hold down - cast-in bolts M 2 x 50 mm minimum or proprietary fixings with a minimum characteristic strength of 5 kN.

  • MiTek Residential Construction Industry We help our customers implement superior processes. With solutions that optimize and control costs, shorten cycle times and eliminate waste, builders achieve more profitable, higher-volume business results, and deliver more affordable, legacy-quality homes.

  • Shadowclad Specifi ion and inStallation Guide Shadowclad& 174; Specifi ion and inStallation Guide For Cavity ConstruCtion SEPTEMBER 2015 information contained within is specific to shadowclad& 174; structural plywood products and must not be used with any other plywood products, no matter how similar they may appear.

  • Flooring Systems - Sika SIKAFLOOR MORRITEX A seamless coating system that combines performance, versatility for high-demand commercial and industrial settings. Morritex is the optimum coating system designed for conditions whether the surface must tolerate significant traffic, large equipment, abrasion, or harsh chemicals. Sikafloor Morritex surfaces are finished with state-of-the-art, sealers for increased wear

  • Ecoply UK Ltd - Telford - Roofing Contractors Find Ecoply UK Ltd on construction.co.uk. Get contact details, gallery, services and general information. Find Ecoply UK Ltd, Telford in the Roofing Contractors sector Merlin Repair Specialists Ltd 10th Floor, 3 Hardman Street Spinningfields, Manchester, M33HF

  • ECOPLY SPECIFICATION and INSTALLATION GUIDE - Ecoply 19 mm Longspan Flooring and 15 mm Ecoply Roofing are F111 stress grade See Tables 1, 4 and 5 . Other Ecoply products are also available in F111 upon request Thickness - ranging from 7 mm to 25 mm. Thicknesses above 25 mm subject to availability Length - being 2400 mm and 2700 mm with a standard nominal width of 1200 mm文件大小: 2MB

  • Structural Plywood Properties and Appli ions Manual Ecoply& 174;Structural plywood is a layered panel made from Pinus radiatawood veneers. The veneers are bonded together with synthetic phenolic PF resin set and cured under heat and pressure in controlled conditions to form a strong and durable Type A bond.

  • Floor levels and clearances BRANZ Weathertight Floor levels Getting the floor level wrong can lead to on-going moisture problems. It can also bring serious Building Code compliance problems and potential drainage problems due to an insufficient height of the floor above ground and lack of fall to the drains.

  • Plumbing CAD Details A--2"re-vent.3'-6"above floor B--2"Vent, 6" Through Roof& 10" from cooler C--3"Cleanout 0--11/2"Waste Line E--SanitaryTee F--FittingDouble fixture G--CombinationWye & eighth Bend H--2"Clothes WasherTrap 6" to 10" above floor 1--2"Clothes Washer Standpipe J--1/1/2"Plumbing Vent 6" above Roof K--2"Cleanout L--SanitaryTee M--2"waste Line N--2

  • PLYfloor Installation Guide 20 4.pdf - Forest o Avoid nail popping. Blocking nogs - refer to Detail o Block all edges of standard "square edge" Ecoply structural plywood. o Block if the floor is being used

  • ECOPly aNd UNder Floor HeaTiNg - chhply.com.au Ecoply& 174; Flooring contains a thermosetting Phenol formaldehyde adhesive that is fully cured in a hot press at over 140 degrees Celsius. The bond is not reversible subjected to normal exterior climatic cycles. On this basis, heating ducts or elements in the floor will have little or no effect on the Phenolic glue line durability. Conversely,

  • Structural Plywood Properties and Appli ions Manual - Dashwood Ecoply Flooring products are also available in F on request. Thickness, ranging Refer to the Shadowclad Specifi ion and Installation Manual for details.

  • Ecoply& 174; Flooring & 187; Plywood NZ Ecoply& 174; Flooring is ideal as a substrate for most floor coverings and flexible waterproofing membranes. It is particularly ideal for wet areas, where treated flooring is needed. It is also widely used for flexible and rigid overlay products such as carpets, linoleum, tiles and membrane systems or any appli ion where a smooth substrate is required.

  • PDF BRANZ Appraisals Product Ecoply& 174; Barrier for Steel Plywood and Cladding Fixing 7.13 Ecoply& 174; Barrier for Steel panels must be fixed at a maximum of 150 mm centres around the perimeter of each panel and at maximum 300 mm centres to intermediate studs. In ‘Extra High’ Wind Zones, the fixing centres on the intermediate studs must be reduced to a maximum of 150 mm

  • sheet products - PDF4PRO Easycraft. Carter Holt Harvey EcoPly PLY FLOOR T and G F 2400 x 200 x 5.0mm SPANS 520mm and fix to timber or steel framing at 600mm centres. Corner details are simple to achieve with a protective aluminium profile and silicone.

  • Ecoply& 174; Plywood & 187; Plywood AU Ecoply Non-Structural plywood is manufactured for building appli ions which do not require specific structural properties such as temporary hoardings, non-structural packaging, DIY projects and temporary weather proofing for damaged buildings. It is available untreated and in a range of thicknesses from 7mm to 25mm.

  • Flooring panels – Ecoply Plyfloor by Carter Holt Harvey Plywood Ecoply Plyfloor is a durable, pre-sanded panel suitable for structural and non-structural flooring in residential, commercial and industrial appli ions, particularly

  • Ecoply Flooring by CHH Plywood – EBOSS Ecoply Flooring is suitable as a substrate for most floor coverings and flexible It is particularly well suited for wet areas, where treated flooring is required, Product · CAD / PDF Details · Installation Details · BIM Installation and Operation.

  • Flooring - Plywood City Ltd Wet Area Flooring Floors in bathrooms, laundry spaces, kitchens and garages are exposed to water occasionally. Use H3 treated Ply Structural or Ply Flooring plywood panels where the exposure is likely to be regular or uncontrolled. For rental accommodation, motels and commercial residential floors, H3 treatment is recommended.

  • Ecoply Barrier Rigid Air Barrier BRANZ Ecoply Barrier has been appraised for use as a rigid wall underlay, air barrier and temporary weather-protecting sheathing on timber-framed buildings within the following scope: The scope limitations of NZBC Acceptable Solution E2/AS1 paragraph 1.1.

  • Engineering Details - US View Engineering Details. View the following detail guides. Some of these standard details may be sealed upon request. Contact MiTek Engineering Support for any questions.. Roof Truss Repair Details

  • Pros and cons of wet area floor finishes - Level Compressed sheet is not used as finished flooring, but it provides a stable substrate for floor finishes. Although less susceptible to moisture damage than timber or timber-based products, it is not an impervious material. Vinyl. Vinyl is an impervious, water-resistant material that is ideal as a wet area floor finish.

  • Fast & Weathertight Builds With Ecoply Rigid Air Barrier Ecoply Barrier – a rigid air barrier system for weathertight buildings Ecoply Barrier is a weathertight, plywood-based, rigid air barrier solution designed to cope with the wet weather and high winds that batter New Zealand homes, businesses and public spaces. Made Tough. Made to Last. Discover More.

  • Cladding penetrations BRANZ Weathertight Sep 09, 2014 & 0183;& 32;Designers will incorporate openings in a direct-fixed cladding at:. window and door penetrations inter-storey junctions at the bottom edges of the cladding. These openings incorporate deflection devices such as window head and sill flashings that allow air to enter and water to drain out but deflect rainwater away and protect the junction between the penetration and the cladding.

  • Ecoply Roofing by CHH Plywood – EBOSS Ecoply Roofing is designed for roofing overlays which can cope with open imperfections in the substrate face. For roofing products which require a smooth substrate such as flexible membranes, use Ecoply Flooring or Ecoply Structural Square Edge CD grade .

  • PLYfloor Installation Guide - Dindas PLYfloor may be fixed to different types of framing with nails or screws or a combination of fasteners and elastomeric adhesive. Do not over-drive gun-nails or screws. Fix at least 7 mm or 3 fastener diameters from the sheet edges or behind …

  • PDF ECOPly aNd UNder Floor HeaTiNg - chhply.com.au fixing, swelling and sheet expansion may occur. This would be followed by shrinkage that could cause problems in the movement of framing and fittings. likewise, it is highly recommended that kiln dry framing e.g. laserframe be used with heated floors. if the ecoply Flooring is kept dry prior to fixing heating hardware and during construction

  • PDF Southland Times Building Strengthening Concept to 100%NBS 1st Floor Diaphragm repairs: Repair perimeter of all 1st floor diaphragms similar to as shown in 1st floor plan adjacent to acheive 800mm c/c or 600c/c as indi ed on table above including existing connections around all perimeters. Note existing anchor condition to be assessed to ensure adequacy. Replace remove flooring with min. 15mm Ecoply

  • Plywood Flooring - YouTube See more pics & details here: Ecoply flooring is a purpose designed strong, stiff and stable structural plywoodpanel . It incorporates special features such as grooved edges, a plastic

  • Cladding penetrations BRANZ Weathertight Designers will incorporate openings in a direct-fixed cladding at:. window and door penetrations inter-storey junctions at the bottom edges of the cladding. These openings incorporate deflection devices such as window head and sill flashings that allow air to enter and water to drain out but deflect rainwater away and protect the junction between the penetration and the cladding.

  • ECOPLY SPECIFICATION & INSTALLATION GUIDE - Ecoply 19 mm Longspan Flooring and 15 mm Ecoply Roofing are F111 stress grade See Tables 1, 4 and 5 . Other Ecoply products are also available in F111 upon request Thickness - ranging from 7 mm to 25 mm. Thicknesses above 25 mm subject to availability Length - being 2400 mm and 2700 mm with a standard nominal width of 1200 mm

  • Ecoply Plywood Plywood AU Ecoply products excluding the non-structural range are produced and certified to AS/NZS 2269 and AS 6669. Structural Square Edge Ecoply Structural Square Edge plywood is commonly selected for uses such as bracing, interior linings, membrane substrates, hoardings and DIY projects.

  • Bracing Supplement Document - GIB bracing resistance. The fixing pattern as illustrated below represents the standard fixing pattern as published on page 38-39 of the GIB Site Guide December 2014 . Building investigations following the Canterbury earthquakes have confirmed that not only designated bracing elements such as GS1-N & GS2-N resist lateral forces.

  • Ecoply plywood lining at Weekender Cabin World-class, sustainably certified Seven Trust flooring that sets a new standard for of architectural and construction projects due to their ease of installation. the most demanding architectural requirements, including smooth, curved wave

  • Quality Home Flooring: Vinyl, Laminate, LVT Tarkett Upgrade your home with beautiful flooring styles including LVT, vinyl sheet, and laminate. Tarkett offers quality home flooring products to meet the demands of a busy home including waterproof and scratch resistant floors, along with quick and easy installation options.

  • PDF Plyfloor - ForestOne Block all edges of standard "square edge" Ecoply structural plywood. o. Block if the floor is being used as a diaphragm for lateral wind and earthquake resistance with fixin. g transfer shear across the joints. In this case, details should be specified on dings. o. Use blocking "on the flat" to provide gaps where air flow is needed for

  • ECOPLY SPECIFICATION and INSTALLATION GUIDE 2.2 Sheet Fasteners and Fixing .. 13 2.3 Adhesives Ecoply 19 mm Longspan Flooring and 15 mm Ecoply Roofing which are F111 See Tables 1, 4 and 5 . Other Ecoply products are also available in F11 upon request Table 2B details

  • ECOPly aNd UNder Floor HeaTiNg - chhply.com.au fixing, swelling and sheet expansion may occur. This would be followed by shrinkage that could cause problems in the movement of framing and fittings. likewise, it is highly recommended that kiln dry framing e.g. laserframe be used with heated floors. if the ecoplyFlooring is kept dry prior to fixing heating hardware and during construction

  • Ecoply Flooring Plywood NZ Ecoply Flooring. Ecoply Flooring is ideal as a substrate for most floor coverings and flexible waterproofing membranes. It is particularly ideal for wet areas, where treated flooring is needed. It is also widely used for flexible and rigid overlay products such as carpets, linoleum, tiles and membrane systems or any appli ion where a smooth substrate is required.

  • Plywood Flooring - YouTube Nov 11, 2014 & 0183;& 32;See more pics and details here: Ecoply flooring is a purpose designed strong, stiff and stable structural plywoodpanel . It incorporates special features such as grooved edges, a plastic

  • Structafloor Install Guide - ForestOne timber or metal floor framing systems. For best results with timber frames, deep floor joists 150mm or more such as those used in upper story construction, should be seasoned and gauged. Securely fix floor joists to bearers. The top surface of joists must be level to allow StructaFlor sheets to lie flat and level When installed.

  • Roofing and Decking Manufacturers Installation Guidelines Ecoply structural plywoods meet the requirements of the New Zealand Building. Code Section B Table : ecoply roofing and flooring plywoods. Product and

  • I-Built J-Ply Bracing - NZ Wood Products GIB Handibrac hold-down fixings must be installed in accordance with the manufacturers fixing details for timber or concrete floors to ensure bracing values are achieved. Refer to the installation details. A 3mm gap should be allowed for between J-Ply sheet edges to allow for any expansion in the J-Ply sheet.

  • Ecoply Barrier by CHH Plywood – EBOSS The Ecoply Barrier system provides a weather tight rigid air barrier for drained and vented cavity systems outside the building frame. It replaces traditional building wrap in the cavity while providing superior structural bracing and forming a strong secondary line of defence against moisture penetration into the building envelope.

  • Structural Plywood Properties & Appli ions Manual Ecoply Flooring products are also available in F11 on request. Thickness, ranging from 4mm to 25mm. Length, being 2400mm and 2700mm with a standard width of 1200mm. Preservative treatment, being untreated, H3 CCA or H3 LOSP Azole treated. Edge finish, being square edge or for Ecoply Flooring, Ecoply Roofing, routed on the

  • TIMBER DECKING FIXING INSTRUCTIONS - Metsä Wood Fixing type: 4.5 x 63mm Stainless Steel or coated deck screws Pilot holes: yes Fixing points: Minimum 15mm from end and minimum 20mm from edge Fixing detail: 2 per joist through face of board . Note: where more than two boards are fixed in a run, a min 6mm gap is required for all our timber boards.

  • Flooring Fixings - Industry Support Frictional fixing clips are the most common method for fixing open grid flooring. The fixing assembly consists of a universal bottom clip Type 5 , M8 hex nut, bolt and a top clip. The top clip is interchangeable and should be selected to suit each particular open mesh flooring. Below is a selection of our main top clips.

  • Southland Times Building Strengthening Concept to 100%NBS 1st Floor Diaphragm repairs: Repair perimeter of all 1st floor diaphragms similar to as shown in 1st floor plan adjacent to acheive 800mm c/c or 600c/c as indi ed on table above including existing connections around all perimeters. Note existing anchor condition to be assessed to ensure adequacy. Replace remove flooring with min. 15mm Ecoply

  • BARRIER floors and 150mm x 12mm galvanised coach screw for timber floors. Fasteners. 5.1 TAPES The Ecoply Barrier – Sill Tape, Frame Sealing Tape and Sealing Tape transform our sheathing plywood panels into a seamless protective barrier for your construction project. All tapes are proven to deliver an airtight and watertight seal. The Ecoply

  • Ecoply Flooring Plywood NZ Ecoply Flooring is ideal as a substrate for most floor coverings and flexible waterproofing membranes. It is particularly Ridge detail with Ridgeboard. DWG DXF PDF Ecoply Specifi ion and Installation Guide September 20 5. Ecoply is

  • The fire resistance rating of FBL-100 protected wall and Perimeter fixing ‐ 50mm x 8g 304 s/s countersunk screws 150mm centres. Mid sheet fixing ‐ 50mm x 8g 304 s/s countersunk screws 400mm centres. 3 Name 12mm or thicker H2 Ecoply Material Structural plywood Installation Perimeter fixing ‐ 40mm x 8g square drive screws 200mm centres.

  • Fast and Weathertight Builds With Ecoply& 174; Rigid Air Barrier Ecoply& 174; Barrier – a rigid air barrier system for weathertight buildings Ecoply& 174; Barrier is a weathertight, plywood-based, rigid air barrier solution designed to cope with the wet weather and high winds that batter New Zealand homes, businesses and …

  • Ecoply Bracing Specifi ion EP1 - organonarchitecture.co.nz types to be used for either concrete or timber floors. Within the length of the bracing element, bottom plates are fixed in accordance with the requirements of NZS 3604:1999. Lining One layer 7mm Ecoply structural ply wood or 12mm Shadowclad exterior wall cladding fixed directly to framing or over cavity battens.

  • PLYfloor Installation Guide - Dindas flooring sheet, or glue-nail the floor to increase stiffness and minimise squeaking, and stretch the foil flat under the joists. Use timber sheets or strips of a low grade of non-structural plywood 7 mm pallet grade to fix the foil to the underside of the floor. Alternatively, use foil backed panels under the floor or a different type of

  • BRANZ Appraisals Product Ecoply Barrier for Steel Plywood and Cladding Fixing 7.13 Ecoply Barrier for Steel panels must be fixed at a maximum of 150 mm centres around the perimeter of each panel and at maximum 300 mm centres to intermediate studs. In ‘Extra High’ Wind Zones, the fixing centres on the intermediate studs must be reduced to a maximum of 150 mm

  • EcoplyFlooring by CHH Plywood – EBOSS EcoplyFlooring is suitable as a substrate for most floor coverings and flexible waterproofing membranes. It is particularly well suited for wet areas, where treated flooring is required, and is widely used for flexible and rigid overlay products such as carpets, linoleum, tiles and membrane systems or any appli ion where a smooth

  • RAB Board James Hardie RAB Board is a solid fibre cement pre-cladding that now comes in two thicknesses; 6 and 9mm. Mostly used for commercial builds, and residential builds exposed to extra high EH wind zones, RAB Board has several key advantages over alternative products.

  • Commercial Flooring Contractor Agrees to Plead Guilty to Aug 19, 2019 & 0183;& 32;PCI FlorTech Inc., an Illinois-based commercial flooring contractor, has been charged for its role in a long-running conspiracy to rig bids and fix prices for commercial flooring services and products sold in the United States, the Department of Justice announced today.

  • hyJOIST I-Beam LVL Floor joists, rafters NZ Made Futurebuild designIT for Commercial Floors Installation Guide. This guide provides a variety of details specific to the use of Futurebuild LVL floor systems for Futurebuild LVL Kaikoura Island Case Study Futurebuild and Ecoply Barrier March 20 8.

  • Glass Flooring Systems Glass Flooring CAD Details The Glass Flooring Systems CAD Details below are complete dings that can easily be downloaded, customized for your residential or commercial project, and included in your CAD library for future use. By downloading and using any ARCAT CAD content you agree to the following license agreement

  • PDF I-Built J-Ply Bracing - NZ Wood Products & 174;GIB Handibrac hold-down fixings must be installed in accordance with the manufacturers fixing details for timber or concrete floors to ensure bracing values are achieved. Refer to the installation details. A 3mm gap should be allowed for between J-Ply sheet edges to allow for any expansion in the J …

  • Plywood Structural Manual qvndp81dp5nx EcoplyFlooring is a good substrate for harder wearing flooring overlays, and is not really suited to clear finishing, especially if it gets exposed to construction moisture first. Ceramic tiles can be laid directly onto 17mm Ecoply Flooring over joists at 450mm centres without the use of tile underlay board for domestic housing